[1]张亚平,党逸峰,姬长发,等.太阳能热管采暖系统的热性能分析[J].西安科技大学学报,2017,(05):755-759.[doi:10.13800/j.cnki.xakjdxxb.2017.0524]
 ZHANG Ya-ping,DANG Yi-feng,JI Chang-fa,et al.Analysis on performance of solar heat pipes heating system[J].Journal of Xi'an University of Science and Technology,2017,(05):755-759.[doi:10.13800/j.cnki.xakjdxxb.2017.0524]
点击复制

太阳能热管采暖系统的热性能分析(/HTML)
分享到:

西安科技大学学报[ISSN:1672-9315/CN:61-1434/N]

卷:
期数:
2017年05期
页码:
755-759
栏目:
出版日期:
2017-09-30

文章信息/Info

Title:
Analysis on performance of solar heat pipes heating system
文章编号:
1672-9315(2017)05-0755-05
作者:
张亚平党逸峰姬长发谭飞鹏
西安科技大学 能源学院,陕西 西安 710054
Author(s):
ZHANG Ya-pingDANG Yi-fengJI Chang-faTAN Fei-peng
College of Energy Science and Engineering,Xi'an University of Science and Technology,Xi'an 710054,China
关键词:
热管 辐射采暖 太阳能 热性能
Keywords:
Key words:heat pipe radiant heating solar energy thermal property
分类号:
TK 511
DOI:
10.13800/j.cnki.xakjdxxb.2017.0524
文献标志码:
A
摘要:
太阳能的利用中普遍受到气候因素制约,导致夏季过热而冬季易结冰的问题,基于此设计了一种新型气液分离式热管采暖系统,热管内的传热气相工质和液相工质分开流动,这种热管采暖系统有效避免了毛细极限和携带极限的影响,对比普通地暖管、单热管、两根热管以及在改变混凝土块面积情况下加热混凝土块表面温度特性实验测试,结果表明热管具有更好的导热性能,可以利用热阻小的特点来降低供暖的热水温度,从而达到节能的目的。实验证明了铜-水热管采暖系统的高效换热效率和快速热响应性能。热管式采暖系统对于提高热效率和室内舒适度具有重要意义,同时利于采暖系统的安全和高效运行。
Abstract:
Abstract:Solar energy utilization is generally restricted by climate factors,leading to overheating in summer and freezing in winter.Based on this problem,a new gas-liquid separator type heat pipe heating system is designed.The flow of the liquid phase and the gas phase is separated in the heat pipe,it can effectively prevent the impact of capillary limit and entrainment limit.The test was conducted and the temperature characteristics was compared in different types,quantities and areas.It was indicated that heat pipe has better thermal conductivity,low thermal resistance characteristics and can be used to reduce the heating temperature of water,so as to achieve energy-saving purpose.The results show that the copper-water heating system has high efficiency heat exchange and rapid thermal response.The heat pipe heating system has important significance for improving heat efficiency and indoor comfort,moreover it is favorable for safe and efficient operation of the heating system.

参考文献/References:

[1] 亢燕铭,沈恒根,徐惠英,等.地板辐射供暖的节能效应分析[J].暖通空调,2001,31(4):4-6. KANG Yan-ming,SHEN Heng-gen,XU Hui-ying,et al.Analysis of energy saving effects of floor panel heating[J].Journal of Heating Ventilation Air Conditioning,2001,31(4):4-6.
[2] 张亚平,余小玲,冯全科.热管热性能的实验研究[J].西安科技大学学报,2007,27(2):187-189. ZHANG Ya-ping,YU Xiao-ling,FENG Quan-ke.Experiment of heat pipe thermal performance[J].Journal of Xi'an University of Science and Technology,2007,27(2):187-189.
[3] 周景民,孙世梅,孙慧晶.热管技术在暖通空调领域中应用与发展前景[J].长春工业大学学报:自然科学版,2007,28(s1):1-7. ZHOU Jing-min,SUN Shi-mei,SUN Hui-jing.Application and prospective of heat pipe technique in HV&AC[J].Journal of Changchun University of Technology:Natural Science Edition,2007,28(s1):1-7.
[4] 杨立权,王 琪,刘姗姗.太阳能采暖系统应用现状及发展[J].农业与技术,2016,36(1):169-171. YANG Li-quan,WANG Qi,LIU Shan-shan.Application and development of solar heating system[J].Journal of Agriculture and Technology,2016,36(1):169-171.
[5] Ma H,Yin L,Shen X,et al.Experimental study on heat pipe assisted heat exchanger used for industrial waste heat recovery[J].Applied Energy,2016,169(1):177-186.
[6] 张亚平,冯全科,余小玲.用于电子冷却的热管性能分析[J].流体机械,2008,36(8):79-82. ZHANG Ya-ping,FENG Quan-ke,YU Xiao-ling.Thermal performance analysis of heat pipe used in electronics cooling[J].Fluid Machinery,2008,36(8):79-82.
[7]Akyurt M,Lamfon N J,Najjar Y S H,et al.Modeling of waste heat recovery by looped water-in-steel heat pipes[J].International Journal of Heat and Fluid Flow,1995,16(4):263-271.
[8]ZHANG Xing-xing,ZHAO Xu-dong,SHEN Jing-chun,et al.Dynamic performance of a novel solar photovoltaic/loop-heat-pipe heat pump system[J].Applied Energy,2014,114(2):335-352.
[9] Brian S Robinson,Nicholas E Chmielewski,Andrea Knox-Kelecy.Heating season performance of a full-scale heat pipe assisted solar wall[J].Solar Energy,2013,87(1):76-83.
[10]Ayompe L M,Duffy A.Thermal performance analysics of a solar water heating system with heat pipe evacuated tube collector using data from a field trial[J].Solar Energy,2013,90:17-28.
[11]赵 薇,张于峰,邓 娜,等.太阳能-低温热管地板辐射供热系统实验研究[J].太阳能学报,2008,29(6):637-643. ZHAO Wei,ZHANG Yu-feng,DENG Na,et al.Experimental investigation on the performance of solar-thermosyphon embedded radiant floor heating system[J].Acta Energiae Solaris Sinica,2008,29(6):637-643.
[12]谭飞鹏.热管应用于太阳能地板辐射供暖的实验研究[D].西安:西安科技大学,2014. TAN Fei-peng.Experiment study of heat pipe applied to solar radiant floor heating system[D].Xi'an:Xi'an University of Science and Technology,2014.
[13]张于峰,谢 慧,李德英,等.碳钢-水热虹吸管传热性能的实验研究[J].天津大学学报,2006,39(2):223-228. ZHANG Yu-feng,XIE Hui,LI De-ying,et al.Experimental investigation on heat transfer performance of carbon-steel/water thermosyphon[J].Journal of Tianjin University,2006,39(2):223-228.
[14]谢 慧.热管地板辐射供暖基础理论研究[D].天津:天津大学,2006. XIE Hui.Study on basic theory of thermosyphon-embedded floor radiant heating[D].Tianjin:Tianjin University,2006.
[15]赵 明,杨 茉,章立新.地板辐射采暖地面散热量的简化计算方法[J].节能技术,2011,29(6):521-525. ZHAO Ming,YANG Mo,ZHANG Li-xin.New method of the floor surface total heat flux calculation[J].Energy Conservation Technology,2011,29(6):521-525.

相似文献/References:

[1]张亚平.用于导电杆的热管热性能分析[J].西安科技大学学报,2009,(01):101.
 ZHANG Ya ping.Analysis of heat pipe thermal performance in use of currentconducting rod[J].Journal of Xi'an University of Science and Technology,2009,(05):101.
[2]张亚平,余小玲,冯全科.热管热性能的实验研究[J].西安科技大学学报,2007,(02):187.[doi:10.3969/j.issn.1672-9315.2007.02.005]
 ZHANG Ya-ping YU Xiao-ling FENG Quan-ke.Experiment of heat pipe thermal performance[J].Journal of Xi'an University of Science and Technology,2007,(05):187.[doi:10.3969/j.issn.1672-9315.2007.02.005]

备注/Memo

备注/Memo:
基金项目:国家自然科学基金(51504188); 陕西省自然科学基金(2014JQ7277) 通讯作者:张亚平(1977-),女,陕西凤翔人,博士,副教授,E-mail:603685433@qq.com