[1]王秋红,张 娟,邓 军,等.基于火灾风险评价理论的城镇消防站选址优化——以山西夏县瑶峰镇为例[J].西安科技大学学报,2014,(06):681-685.[doi:10.13800/j.cnki.xakjdxxb.2014.0609]
 WANG Qiu-hong,ZHANG Juan,DENG Jun,et al.Optimization location of fire fighting stations based on fire risk assessment theory ——A case study of Yaofeng town of Xia city in Shanxi province[J].Journal of Xi'an University of Science and Technology,2014,(06):681-685.[doi:10.13800/j.cnki.xakjdxxb.2014.0609]
点击复制

基于火灾风险评价理论的城镇消防站选址优化——以山西夏县瑶峰镇为例(/HTML)
分享到:

西安科技大学学报[ISSN:1672-9315/CN:61-1434/N]

卷:
期数:
2014年06期
页码:
681-685
栏目:
出版日期:
2014-12-08

文章信息/Info

Title:
Optimization location of fire fighting stations based on fire risk assessment theory ——A case study of Yaofeng town of Xia city in Shanxi province
文章编号:
1672-9315(2014)06-0681-05
作者:
王秋红1张 娟2邓 军1朱红亚3
1.西安科技大学 能源学院,陕西 西安 710054;
2.运城市公安消防支队 政治处,山西 运城 044000;
3.公安部天津消防研究所,天津 300381
Author(s):
WANG Qiu-hong1ZHANG Juan2DENG Jun1ZHU Hong-ya3
1.College of Energy Science and Engineering,Xi'an University of Science and Technology,Xi'an 710054,China;
2.Political Department,Fire Brigade of Yuncheng City,Yuncheng 044000,China;
3.Tianjin Fire Research Institute of the Ministry of Public Security,Tianjin 300381,China
关键词:
火灾风险评价 消防站 优化选址
Keywords:
fire risk assessment fire fighting station optimization location
分类号:
TU 998.1
DOI:
10.13800/j.cnki.xakjdxxb.2014.0609
文献标志码:
A
摘要:
构建瑶峰镇消防重点单位火灾风险指标体系,采用层次分析法评判得出瑶峰镇消防重点单位的火灾风险,排序为易燃易爆场所>商场、集贸市场>公共娱乐场所>学校、幼儿园>宾馆饭店>重要机关>高层住宅建筑。以火灾风险性最高的易燃易爆场所为重点消防对象,使用ArcGIS软件和传统消防站布局法,对瑶峰镇进行消防站优化选址。研究结果表明无论4 km2还是7 km2的消防站责任区面积,瑶峰镇城区都需要建设两个消防站,比原有消防站在位置上有很大的变动。在ArcGIS系统中的道路布局图上,可以确切得到新消防站的具体建设位置,为瑶峰镇政府建设新消防站提供优化决策。
Abstract:
Fire risk index system of key enterprises in Yaofeng town was constructed,then the fire risk rank of key enterprises was acquired using the analytical hierarchy process,that is,inflammation and explosive bursting>shopping malls and markets>public entertainment places>schools and kindergartens>hotels and restaurants>administrative organizations and institutions>high-rise residential buildings.Furthermore,new locations of fire fighting stations were confirmed by using ArcGIS software and traditional fire station placement method according to inflammation and explosive bursting.The results show that no matter the responsibility area of fire fighting station is 4 km2 or 7 km2,two fire fighting stations should be built in Yaofeng town,the new stations locations are greatly different from the current station.The alterable locations were accurately displayed on the map of ArcGIS software,which provided the optimization decision about the development of fire fighting stations for Yaofeng government.

参考文献/References:

[1] Bukowski R W,Stiefel S W,Hall J R,et al.Fire risk assessment method:description of methodology[M].Quincy:National fire protection association,1999.
[2] Michael S W.Dwelling Risk Assessment Toolkit[M].London:Fire Policy Unit,1999.
[3] 杜 霞,张 欣,刘庭全.国外区域火灾风险评估技术及应用现状[J].消防科学与技术,2004,23(2):137-139. DU Xia,ZHANG Xin,LIU Ting-quan.The current status and applying of city fire risk assessment technology in foreign country[J].Fire Science and Technology,2004,23(2):137-139.
[4] 李 杰,宋建学.城市火灾危险性分析[J].自然灾害学报,1995,4(2):99-103. LI Jie,SONG Jian-xue.Hazard analysis of urban fire disaster[J].Journal of Natural Disasters,1995,4(2):99-103.
[5] 张一先,王建平,方宗堂,等.城市定量火灾安全评估方法——以苏州古城区为例[J].苏州科技学院学报,2003,16(4):27-32. ZHANG Yi-xian,WANG Jian-ping,FANG Zong-tang,et al.On quantitative assessment of urban fire prevention-taking ancient downtown area as a fit example[J].Journal of University of Science and Technology of Suzhou,2003,16(4):27-32.
[6] 李华军,梅 宁,程晓舫.城市火灾危险性模糊综合评价[J].火灾科学,1995(2):44-50. LI Hua-jun,MEI Ning,CHENG Xiao-fang.Fuzzy assessment method for urban fire risks in cities[J].Fire Safety Science,1995(2):44-50.
[7] 杨 海.火灾风险不确定性分析研究[D].哈尔滨:哈尔滨工业大学,2002. YANG Hai.Research on uncertainty analysis of fire risk[D].Harbin:Harbin Institute of Technology,2002.
[8] 杨 立.开封市城市火灾危险性分析[D].西安:西安建筑科技大学,2005. YANG Li.Hazard analysis of urban fire disaster of Kaifeng[D].Xi'an:Xi'an University of Architecture & Technology,2005.
[9] 陈志芬,陈 晋,黄崇福,等.大型公共场所火灾风险评价指标体系(Ⅱ)[J].自然灾害学报,2006,15(2):164-168. CHEN Zhi-fen,CHEN Jin,HUANG Chong-fu,et al.Fire risk assessment index system for large-scale public places(Ⅱ)[J].Journal of Natural disasters,2006,15(2):164-168.
[10]胡传平.区域火灾风险评估与灭火救援力量布局优化研究[D].上海:同济大学,2006. HU Chuan-ping.Research on regional fire risk assessment and fighting rescue strength layout optimization[D].Shanghai:Tongji University,2006.
[11]王大博.火灾风险评估引入消防站布局的实践与思考[D].长春:东北师范大学,2009. WANG Da-bo.Practice and thinking of fire risk assessment introduced into fire fighting station layout[D].Changchun:Northeast Normal University,2009.

备注/Memo

备注/Memo:
收稿日期:2014-09-20 责任编辑:刘 洁
基金项目:陕西省教育厅专项科研计划项目(2013JK09947); 西安科技大学培育基金(201245)
通讯作者:王秋红(1984-),女,陕西西安人,博士,讲师,E-mail:wangqiuhong1025@126.com